精选博文

How Temperature Affects Viscosity

  How Temperature Affects Viscosity: Viscosity can be defined as the internal friction that occurs as a material flow, relative to itself....

2017年8月16日星期三

What’s the Function of a,b,c Tube of Ubbelohde Viscometer

Abstract: B tube is the main part, used to do the flow, and measures the flow time of liquid. The C tube is used to connect the air so that the liquid in the B tube becomes suspended, which reduces turbulence and allows the liquid to flow freely along the wall, resulting in higher accuracy. A tube is filled with liquid. When the fluid is flowing by external force, there is a tangential internal friction between the flowing liquid layers, and if the liquid is to pass through the tube, a portion of the work must be consumed to overcome the resistance of the flow. When the flow rate is low, the liquid in the tube is advanced in a straight line parallel to the tube wall. The liquid closest to the tube wall is actually stationary, and the farther the distance from the tube wall is, the greater the velocity.

B tube is the main part, used to do the flow, which measured the distance from the flow of time.
The C tube is used to connect the air so that the liquid in the B tube becomes suspended, which reduces turbulence and allows the liquid to flow freely along the wall, resulting in higher accuracy.
A tube is filled with liquid.
When the fluid is flowing by external force, there is a tangential internal friction between the flowing liquid layers, and if the liquid is to pass through the tube, a portion of the work must be consumed to overcome the resistance of the flow. When the flow rate is low, the liquid in the tube is advanced in a straight line parallel to the tube wall. The liquid closest to the tube wall is actually stationary, and the distance from the wall is farther and the flow rate is. The tangential force between the flow layers f and the contact area between the two layers A and the speed difference
Δv is proportional to, and inversely proportional to the distance Δx between the two layers:
Where, η is the proportion coefficient, called the viscosity of the liquid coefficient, referred to as viscosity.
The molar mass of the polymer not only reflects the size of the polymer molecule, but also directly related to its physical properties, is an important basic parameter. Unlike conventional inorganic or low molecular organic matter, the polymer is mostly macromolecular mixture of different molar mass, so the measured molar mass of polymer is usually a statistical average.


Kent Yuan (Mr.)
Hangzhou Zhongwang Technology Co., LTD.
P  /Wahtsapp: +86 15068109723  E lei@zonwon.com 
 

    

Coyp right by @Hangzhou Zhongwang Technology CO.,LTD

2017年8月7日星期一

K, α value of Some Common Polymer

K, α value of Some Common Polymer 

Abstract:
Polymer, Polymerization Method, Molecular Weight Range, Solvent Temperature K Value, Polystyrene (PS) Solution Polymerization 3-1700 Toluene 25 ° C 1.7 0.69 1-11 Benzene 25 ° C 4.17 0.60 5.9-5.2 Benzene 20 ° C 1.23 0.72 330-Benzene 30 ° C 1.1 0.73 polymethylmethacrylate bulk polymerization 70-6300 benzene 25 ° C 0.468 0.77 (PMMA) 240-4500 benzene 25 ° C 0.38 0.70 emulsion polymerization 410-3400 acetone 25 ° C 0.96 0.69 410-3400 toluene 25 ° C 0.71 0.73 410-3400 Chloroform 25 ° C 0.34 0.83 styrene-butadiene rubber (SBR) emulsion polymerization 25-500 toluene 25 ° C 5.25 0.66 emulsion polymerization 50 ° C 26-1740 toluene 30 ° C 1.65 0.73 emulsion polymerization 5 ° C 55-1000 toluene 30 ° C 2.95 0.75 natural rubber (NR) 0

Polymer
Polymerization Method
Molecular Weight Range
Solvent
Temperature
K Value
α Value  
Polystyrene (PS)
solution polymerization
3-1700
Toluene
25 ° C
1.7
0.69


1-11
benzene
25 °C
4.17
0.60


5.9-5.2
benzene
20 ° C
1.23
0.72


330-
benzene
30 ° C
1.1
0.73
Poly (methyl methacrylate) (PMMA)
Polymerization
70-6300
Benzene
25 ° C
0.468
0.77


240-4500
benzene
25 ° C
0.38
0.70

Emulsion Polymerization
410-3400
Acetone
25 ° C
0.96
0.69


410-3400
Toluene
25 ° C
0.71
0.73


410-3400
Chloroform
25 ° C
0.34
0.83
Styrene-butadiene rubber (SBR)
emulsion polymerization
25-500
Toluene
25 ° C
5.25
0.66

Emulsion Polymerization 50 ° C
26-1740
Toluene
30 ° C
1.65
0.73

Emulsion Polymerization 5 ° C
55-1000
Toluene
30 ° C
2.95
0.75
Natural rubber (NR)

0.4-1500
Benzene
25 ° C
5.02
0.17

Butadiene rubber (BR)

20-1300
Toluene

25 ° C
2.15
0.65


26-660
Butanone
30 ° C
4.8
0.55
Polyacrylonitrile (PAN)

48-270
Dimethylformamide
25 ° C
1.66
0.81
Polyester (PET)

  3-370 
Dimethylformamide
25 ° C  

2.33
0.75


12-28
Phosphorus Chlorobenzene
25 ° C  
3.0
0.77


 5-25
phenol / tetrachloroethane
25 ° C
2.1
0.82
Polyvinyl alcohol (PVA)

11.6-195
Water
25 ° C
5.95
0.63


44-1100
Water
50 ℃
5.9
0.67


30-120
Water
30 ℃
6.6
0.64


Kent Yuan (Mr.)
Hangzhou Zhongwang Technology Co., LTD.
P  /Wahtsapp: +86 15068109723  E lei@zonwon.com 
 

    

Coyp right by @Hangzhou Zhongwang Technology CO.,LTD

2017年7月31日星期一

The Daily Maintenance of Magnetic Stirrer

The Daily Maintenance of Magnetic Stirrer
Magnetic stirrer is an instrument works under the principle of mixing the material. Suitable for the viscosity is not very large solid-liquid mixture or liquid in the physical magnetic. In the daily usage if the magnetic stirrer broken, we need to calmly deal with, do not be anxious. Some treatment and methods can be used to determine the cause of the failure, so the daily use of magnetic stirrer in the process must also pay attention to do maintenance of magnetic stirrer, extend the equipment Of life as much as possible.

First, the routine maintenance

1.       First static then dynamic: determine the electrical equipment buttons, transformers, thermal relays and the fuse is good or bad, to determine the fault position when the device is not powered. Power test, listen to the sound, test parameters, determine the fault, then maintenance. If the motor phase is missing, if the measured three-phase voltage value can not be identified, it should listen to the sound, individually measured each relative to the voltage, to determine which phase defects.
2.       First the general then special: due to assembly quality or other equipment failure caused by failure, generally account for about 50% of common faults. Electrical equipment, special failures are mostly soft faults, rely on experience and instrumentation to measure and repair.
3.       First cleaning then repairing: for the heavy pollution of electrical equipment, clean its buttons, wiring points, contact points, check the external control keys are malfunctioning. Many failures are caused by dirt and conductive dust.
4.       First Machine then electrical: only in the determination of mechanical parts without failure, and then electrical inspection. Check the circuit failure, you should use the detection equipment to find the fault location, to confirm no contact failure, and then targeted to see the relationship between the operation of the line and machinery to avoid misjudgment.
5.       Thinking first before moving hands: for electric stirrer failure, should not rush to the first hands-on, ask the reason of fault. For unfamiliar equipment, should also be familiar with the circuit principle and structural characteristics, to comply with the corresponding rules, before you disassemble. Familiarize yourself with the function, location, connection, and relationship with other devices in each electrical component. In the absence of an assembly diagram, you should dismantle and sketch the mark.
6.       First debugging then fault: debugging and fault coexistence of electrical equipment, should first remove the fault, and then debugging, commissioning must be carried out under the premise of the electrical line speed.
7.       First external then internal: should first check whether the equipment obvious cracks, defects, to understand its maintenance history, life, etc., and then check the machine internal. Before the demolition should be excluded from the surrounding fault factors, identified as the machine after the failure to disassemble, otherwise, blind disassembly, the equipment may repair the worse.
8.       First power then equipment: the power part of the failure rate in the entire fault equipment accounted for a high proportion, so the first maintenance power can often be more with less.

Second, the maintenance when working

1.   It is best not to let the instrument works in the absence of heating liquid.
2.  The machine should be checked before the operation of the ground, to ensure that after the completion of work.
3.  In order to ensure no damage to the instrument, usually the instrument will be placed inside the insulation material, so the first time we use the magnetic stirrer will find a little smoke or pungent taste, it is normal. Not the Product quality problems, but Keep it ventilated.
4. The magnetic stirrer inside the device heating the upper limit, so in the heating time must be taken into account, the best way is to ensure that the machine is not only heating, and remember the state of the motor into a rotating state, so that The greatest degree of protection of magnetic stirrer.
5.   After the completion of heating, turn off the heat first, and after the temperature has been dispersed and then close the mixing.
6.   To ensure that the environment of the dry. Because in a humid environment, the instrument easily leads to leakage and other phenomena, which is why we must ensure that the instrument grounded, if the instrument is very wet when you must use hot air dry.
7.   The operation must be careful, do not be burned, because the general temperature is relatively high.

8.  For the sake of safety equipment on the back of a fuse, the device is still working after the power can check whether the need to replace.




Kent Yuan (Mr.)
Hangzhou Zhongwang Technology Co., LTD.
P  /Wahtsapp: +86 15068109723  E lei@zonwon.com 
 

    

Coyp right by @Hangzhou Zhongwang Technology CO.,LTD