Zonwon was built on 2009 in Hangzhou,China. Aiming to provide "Auto Lab" for all the research department. We provide sample preparation and measuring instruments,the product line including: IVS Series Ubbelohde viscometer, D25/DP25 Pipette, A6 Furnace, P12 sample dissolving instrument and ,FHJ-8 Tube heater reactor. The best choice for high polymer material sample preparation and viscosity testing.
精选博文
How Temperature Affects Viscosity
How Temperature Affects Viscosity: Viscosity can be defined as the internal friction that occurs as a material flow, relative to itself....
2018年7月20日星期五
DP25 Pipettor
2018年7月7日星期六
Say Something about Viscosity Testing
Hello Anyone who read this article.
I write this article because i have received many question about how to operate our machine.
Why need viscosity testing.
What can viscometer do.
Let’s learn something first.
What is viscosity?
The viscosity of a fluid is the measure of its resistance to gradual deformation by shear stress or tensile stress.-------Wikipedia
What is Ubbelohde viscometer?
An Ubbelohde type viscometer or suspended-level viscometer is a measuring instrument which uses a capillary based method of measuring viscosity.
A liquid is introduced into the reservoir then sucked through the capillary and measuring bulb. The liquid is allowed to travel back through the measuring bulb and the time it takes for the liquid to pass through two calibrated marks is a measure for viscosity.
The Ubbelohde device has a third arm extending from the end of the capillary and open to the atmosphere. In this way the pressure head only depends on a fixed height and no longer on the total volume of liquid.-------Wikipedia
Why testing viscosity?
Gathering viscosity data on a material gives manufacturers the ability to predict how the material will behave in the real world. For example, if toothpaste does not have the correct viscosity, it can either be too difficult to pump out from the tube, or pump out too much.
Knowing the viscosity of a material also affects how the production and transportation processes are designed.
Newtonian and Non-Newtonian fluids.
Isaac Newton, the man to discover this formula, thought that, at a given temperature and shear stress, the viscosity of a fluid would remain constant regardless of changes to the shear rate.
He was only partly right. A few fluids, such as water and honey, do behave this way. We call these fluids Newtonian fluids. Most fluids, however, have viscosities that fluctuate depending on the shear rate. These are called Non-Newtonian fluids.
There are five types of non-Newtonian fluids: thixotropic, rheopectic, pseudoplastic, dilatant, and plastic. Different considerations are required when measuring each of these fluid types.
How many accessories required for Viscosity testing?
Simple, follow the stander.
For example, if we testing the PET viscosity, we following the stander GB 17931 or GB/T 14190 or ASTM D4603 or ISO 1628-5.
All the details and progress were listed on the stander.
Take GB 17931 for example,it’s process as following:
I have oranisged the accessories list as below.
Instruments and Solvent for PET Viscosity Measuring Project
| |||
Prepare the sample
|
Function
| ||
Stander
| |||
Sample Bag
|
12cm*17cm(Suggest)
|
Prepare the sample
| |
Prepare the sample
| |||
Stander
| |||
Sessior
|
11.5cm Scissors
|
cut sample small for dissolving
| |
Sample Preparation
| |||
Stander
| |||
Analytical Balances
|
Precision 0.1mg
|
Sample weighing
| |
Dissolving Bottle
|
50ml or 100 ml Volume
|
Based on ISO1042 stander,With ground glass stopper
|
Hold sample and solvent
|
Weighing paper
|
120mm*120mm(Suggest)
| ||
Conical flask
|
100ml
| ||
Pipette
|
25ml
|
Transfer fix volume liquid
| |
Filter appliance
|
Sand core funnel
|
40um~100um diameter or Stainless steel mesh plug,0.075mm2
|
Filter impurities
|
Sample Dissolving
|
Temp range 0~120℃
|
Dissovling the sample
| |
Electric blast drying box
|
Drying flask with
| ||
Vacuum drying oven
|
Pressure<100kPa
|
If the sample moisture exceeds the standard for drying
| |
Solvent
| |||
Weight 1:1 or 3:2 phenol/tetrachloroethane solution, accurately weighed at least 1%.
|
The density ranges are 1.280 ± 0.003 g/cm3 and 1.235 ± 0.003 g/cm3, At 25 degrees ± 0.02
| ||
Water
| |||
Chromic acid lotion
|
cleaning the ubbelohde tube
| ||
Glass bottle
|
Brown,5000ml
|
solvent storage
| |
Dryer and silicone
|
Hold stander PET chips
| ||
Ethanol
|
AR Stander
|
Cleaning and dry the tubes
| |
Phenol
|
AR Stander
| ||
Tetrachloroethane
|
AR Stander
| ||
Ear wash ball
| |||
Environment Required
| |||
Stander
| |||
Fume hood
|
able acid and alkali corrosion resistance
|
Toxic and hazardous reagents must be operated in a ventilated environment
| |
Air conditioning
|
The experimental environment should be controlled at 25°C
| ||
Tips: the reagent having toxicity test method should avoid contact with skin and inhalation of vapors. Operators should take appropriate safety and health precautions.
| |||
How to choose the viscometer?
First,know what sample you are going to test? It’s it PET or Food?
Our viscometer only applied to test the viscosity of Newtonian liquid
How to use the viscometer?
For more details,please refer to our YouTube Video.
For more details,please feels free to contact.
Kent
WhatApp/Wechat: +86 13388604020